{"product_id":"appleton-efsr-2023-replacement-receptacle-for-efs-assembly","title":"Appleton EFSR-2023 Replacement Receptacle for EFS Assembly","description":"\u003cdiv data-v-2fbf8542=\"\" class=\"text--secondary product-description col col-12\"\u003eU-Line 1-Gang Replacement Receptacle, Number Of Poles: 3, Number Of Wires: 2, Amperage Rating: 20 AMP, Voltage Rating: 125 VAC, Material: Copperfree (4\/10 Of 1 PCT Maximum) Aluminum, Nema Rating: NEMA 3, 3R, Mounting: Box, Motor Horsepower: 1 HP, Finish: Epoxy Powder Coat, Dimensions: 3 IN Width X 4.63 IN Height X 3.19 IN Depth, Standard: Class I, Division 1 And 2 Groups C, D, Class I, Division 2, Groups B, C, D, Class II, Division 1 And 2 Groups F, G, Class III, UL Listed: E10784, E81751, UL Standard: 1203, 1010, 894, CSA Standard: C22.2 No. 25, C22.2 No. 30, C22.2 No. 42, C22 No.159, CSA Certified: 038644, For ECP Mating Plugs\u003c\/div\u003e\n\u003cdiv data-v-2fbf8542=\"\" class=\"text--secondary product-description col col-12\"\u003e\u003c\/div\u003e\n\u003cdiv data-v-2fbf8542=\"\" class=\"text--secondary product-description col col-12\"\u003e\n\u003cmeta charset=\"utf-8\"\u003e\n\u003cdiv class=\"col col-12\"\u003e\n\u003cp\u003eU-Line™ Factory Sealed 20 Amp Plugs and Receptacles are used with stationary or portable electrically operated devices in hazardous locations. The ECP Interchanger plug is designed with built-in switch contacts which activate when the plug is twisted into the receptacle. This design allows the ECP plug to fit into standard NEMA 5-20R and 6-20R receptacles, but does not allow standard plugs to be used with the receptacle, ensuring that only safe connections can be made in a hazardous location.\u003c\/p\u003e\n\u003ctable class=\"roc-two-col-table\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"td-left\" data-testid=\"attribute-type-0\"\u003eMaterial\u003c\/th\u003e\n\u003ctd data-testid=\"attribute-value-0\"\u003e\n\u003cdiv class=\"ck-content\" data-testid=\"rich-text-content\"\u003eAluminum\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"td-left\" data-testid=\"attribute-type-1\"\u003eNumber Of Poles\u003c\/th\u003e\n\u003ctd data-testid=\"attribute-value-1\"\u003e\n\u003cdiv class=\"ck-content\" data-testid=\"rich-text-content\"\u003e3\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"td-left\" data-testid=\"attribute-type-2\"\u003eVoltage Rating\u003c\/th\u003e\n\u003ctd data-testid=\"attribute-value-2\"\u003e\n\u003cdiv class=\"ck-content\" data-testid=\"rich-text-content\"\u003e125 VAC\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"td-left\" data-testid=\"attribute-type-3\"\u003eAmperage Rating\u003c\/th\u003e\n\u003ctd data-testid=\"attribute-value-3\"\u003e\n\u003cdiv class=\"ck-content\" data-testid=\"rich-text-content\"\u003e20 A\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"td-left\" data-testid=\"attribute-type-4\"\u003eHorsepower\u003c\/th\u003e\n\u003ctd data-testid=\"attribute-value-4\"\u003e\n\u003cdiv class=\"ck-content\" data-testid=\"rich-text-content\"\u003e1 hp\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"td-left\" data-testid=\"attribute-type-5\"\u003eNEMA Rating\u003c\/th\u003e\n\u003ctd data-testid=\"attribute-value-5\"\u003e\n\u003cdiv class=\"ck-content\" data-testid=\"rich-text-content\"\u003eNEMA 3\/3R\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"td-left\" data-testid=\"attribute-type-6\"\u003eNumber of Wires\u003c\/th\u003e\n\u003ctd data-testid=\"attribute-value-6\"\u003e\n\u003cdiv class=\"ck-content\" data-testid=\"rich-text-content\"\u003e2\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"td-left\" data-testid=\"attribute-type-7\"\u003eApplication\u003c\/th\u003e\n\u003ctd data-testid=\"attribute-value-7\"\u003e\n\u003cdiv class=\"ck-content\" data-testid=\"rich-text-content\"\u003eFor ECP mating plugs\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"td-left\" data-testid=\"attribute-type-8\"\u003eStandard \u0026amp; Approvals\u003c\/th\u003e\n\u003ctd data-testid=\"attribute-value-8\"\u003e\n\u003cdiv class=\"ck-content\" data-testid=\"rich-text-content\"\u003eClass I, Division 1 and 2 Groups C, D, Class I, Division 2, Groups B, C, D; Class II, Division 1 and 2 Groups F, G, Class III, CSA C22.2 No.25, C22.2 No. 30, C22.2 No.42, C22 No.159 Certified File No. 038644, RoHS Compliant, UL 1203, 1010, 894 File No. E10784, E81751 Listed\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth scope=\"row\" class=\"td-left\" data-testid=\"attribute-type-9\"\u003eDimensions\u003c\/th\u003e\n\u003ctd data-testid=\"attribute-value-9\"\u003e\n\u003cdiv class=\"ck-content\" data-testid=\"rich-text-content\"\u003e4.63 in H x 3 in W x 3.19 in D\u003c\/div\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Appleton Electric","offers":[{"title":"Default Title","offer_id":41962752311399,"sku":"RWEFSR-2023","price":285.37,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0632\/7975\/9463\/files\/appefsr2023.jpg?v=1765172905","url":"https:\/\/www.riswll.com\/products\/appleton-efsr-2023-replacement-receptacle-for-efs-assembly","provider":"Redwood Industrial Solutions W.L.L","version":"1.0","type":"link"}