{"product_id":"brady-66320-multi-pole-breaker-lockout-clamp-on-for-120-277v-ac-volt-6-pk","title":"Brady 66320 Multi-Pole Breaker Lockout Clamp-On, For 120\/277V AC Volt, 6 PK","description":"\u003cdiv data-v-4278c13e=\"\" data-v-5b70a167=\"\" class=\"product-description\"\u003e\n\u003cdiv data-v-4278c13e=\"\" class=\"description-text pt-4 pl-2 pl-lg-4\"\u003eMulti-Pole Breaker Lockout, Circuit Breaker Lockout Type Clamp-On, For Circuit Breaker Type Multipole, For Maximum Padlock Shackle Diameter 9\/32 in, For Voltage 120\/277V AC, Maximum Number of Padlocks 2, Overall Height 1.05 in, Overall Length 2.25 in, Overall Width 2.45 in, Features Isolates and Secures Circuit Breaker Switches, For Use With Three-Pole Breakers with Tie-Bar, Two-Pole Breakers with Tie-Bar, Lockout Color Red, Lockout Material Glass-Filled Nylon, Maximum Temperature 248 Degrees F\u003c\/div\u003e\n\u003cdiv data-v-4278c13e=\"\" class=\"description-text pt-4 pl-2 pl-lg-4\"\u003e\u003c\/div\u003e\n\u003cdiv data-v-4278c13e=\"\" class=\"description-text pt-4 pl-2 pl-lg-4\"\u003e\n\u003ctable data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"100%\" class=\"mb-4\"\u003e\n\u003ctbody data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" class=\"text-body-1\"\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eMaximum Number of Padlocks\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eMaterial\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eNylon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eMax. Number of Padlocks\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eLockout Material\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eGlass-Filled Nylon\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eLockout Color\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eFor Use With\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eThree-Pole Breakers with Tie-Bar, Two-Pole Breakers with Tie-Bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eColor\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eRed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eStandards\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eANSI Z244, OSHA 29 CFR 1910.147 (C) (4) (ii) (A) (1) \/ (c) (5) (ii) (C) (1)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eCircuit Breaker Voltage\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003e120\/277\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eOSHA Compliant\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eLockout Type\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eClamp-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eCircuit Breaker Lockout Type\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eClamp-On\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eResistance Properties\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eChemical Resistant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eFor Voltage\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003e120\/277V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eMinimum Temperature\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003e-4 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eMount Type\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eTie Bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eFor Circuit Breaker Type\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eMultipole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eFeatures\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eIsolates and Secures Circuit Breaker Switches\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eMaximum Temperature\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003e248 Degrees F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr data-v-5b70a167=\"\" data-v-4a44d745-s=\"\"\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 px-lg-4 font-weight-bold\"\u003eProducts By Industry\u003c\/td\u003e\n\u003ctd data-v-5b70a167=\"\" data-v-4a44d745-s=\"\" width=\"50%\" class=\"pa-2 pl-4 pr-lg-4 pl-lg-0\"\u003eElectrical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Brady","offers":[{"title":"Default Title","offer_id":41962625269863,"sku":"RW1D671","price":84.2,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0632\/7975\/9463\/files\/15Y515_AS01-546519.jpg?v=1765168542","url":"https:\/\/www.riswll.com\/products\/brady-66320-multi-pole-breaker-lockout-clamp-on-for-120-277v-ac-volt-6-pk","provider":"Redwood Industrial Solutions W.L.L","version":"1.0","type":"link"}