{"product_id":"leeson-056c17g15523-hazardous-location-motor-1-2-hp-1725-rpm-115-208-230v-single-phase-capacitor-start-tefc-frame-56-class-i-ii-div-i","title":"Leeson 056C17G15523 Hazardous Location Motor, 1\/2 HP, 1725 RPM, 115\/208-230V, Single Phase, Capacitor-Start, TEFC, Frame 56, Class I\/II Div I","description":"\u003cp\u003eHazardous Location Motor, Single Phase, Motor Design Capacitor-Start, 1\/2 hp HP, Nameplate RPM 1,725 RPM, No. of Speeds 1, Voltage 115\/208-230V AC, Full Load Amps 8.8\/4.2-4.4 A, 56 Frame, Usable @ 208V Usable at 208V, Usable @ 200V Not Usable at 200V, Hz 60 Hz, Max. Ambient Temp. 40 Degrees C, Motor Service Factor 1, Motor Thermal Protection Auto, Ins. Class B, Hazardous Location Class Class I, Class II, Temp. Code T3B, Motor Enclosure Design Totally Enclosed Fan Cooled, Duty Cycle Continuous\u003c\/p\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Design\u003c\/th\u003e\n\u003ctd\u003eCapacitor-Start\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePhase\u003c\/th\u003e\n\u003ctd\u003eSingle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHP\u003c\/th\u003e\n\u003ctd\u003e1\/2 hp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eRPM Range\u003c\/th\u003e\n\u003ctd\u003e1,701-1,800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e115\/208-230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame\u003c\/th\u003e\n\u003ctd\u003e56\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHazardous Location Class\u003c\/th\u003e\n\u003ctd\u003eClass I, Class II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Thermal Protection\u003c\/th\u003e\n\u003ctd\u003eAuto\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Enclosure Design\u003c\/th\u003e\n\u003ctd\u003eTotally Enclosed Fan Cooled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Mounting Type\u003c\/th\u003e\n\u003ctd\u003eRigid Base\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStandards\u003c\/th\u003e\n\u003ctd\u003eCSA Certified (LR47504), UL Listed (E12044)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Application\u003c\/th\u003e\n\u003ctd\u003eHazardous Location\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Shaft Rotation\u003c\/th\u003e\n\u003ctd\u003eCW\/CCW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemp. Code\u003c\/th\u003e\n\u003ctd\u003eT3B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Service Factor\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty\u003c\/th\u003e\n\u003ctd\u003eContinuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Frame Material\u003c\/th\u003e\n\u003ctd\u003eSteel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Bearings\u003c\/th\u003e\n\u003ctd\u003eBall\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage Compatibility\u003c\/th\u003e\n\u003ctd\u003e115\/200-230V AC, 115\/208-230V AC, 115V AC, 208-230V AC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFull Load Amps\u003c\/th\u003e\n\u003ctd\u003e8.8\/4.2-4.4 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHz\u003c\/th\u003e\n\u003ctd\u003e60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMax. Ambient Temp.\u003c\/th\u003e\n\u003ctd\u003e40 Degrees C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Shaft Design\u003c\/th\u003e\n\u003ctd\u003eKeyed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eFrame Material\u003c\/th\u003e\n\u003ctd\u003eRolled steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIns. Class\u003c\/th\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eIncludes\u003c\/th\u003e\n\u003ctd\u003eConduit Box, Leads through 1 in NPT Nipple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNameplate RPM\u003c\/th\u003e\n\u003ctd\u003e1,725 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNominal Efficiency\u003c\/th\u003e\n\u003ctd\u003e85.5 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDuty Cycle\u003c\/th\u003e\n\u003ctd\u003eContinuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUsable @ 200V\u003c\/th\u003e\n\u003ctd\u003eNot Usable at 200V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e28.93 lb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eUsable @ 208V\u003c\/th\u003e\n\u003ctd\u003eUsable at 208V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eNo. of Speeds\u003c\/th\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor Mounting Position\u003c\/th\u003e\n\u003ctd\u003eHorizontal\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConduit Box Location\u003c\/th\u003e\n\u003ctd\u003eExterior\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHazardous Location Division\u003c\/th\u003e\n\u003ctd\u003eDivision I\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eHazardous Location Group\u003c\/th\u003e\n\u003ctd\u003eGroup C, Group D, Group E, Group F, Group G\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCountry of Origin\u003c\/th\u003e\n\u003ctd\u003eUnited States\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Leeson","offers":[{"title":"Default Title","offer_id":43769958826087,"sku":"RW1TUN1","price":767.92,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0632\/7975\/9463\/files\/1TUL1_AS01.jpg?v=1778897077","url":"https:\/\/www.riswll.com\/products\/leeson-056c17g15523-hazardous-location-motor-1-2-hp-1725-rpm-115-208-230v-single-phase-capacitor-start-tefc-frame-56-class-i-ii-div-i","provider":"Redwood Industrial Solutions W.L.L","version":"1.0","type":"link"}