Cooper SH66A FDA Digital Thermistor Thermometer, -40 to 300 Degrees F
Original price
$385.59
-
Original price
$385.59
Original price
$385.59
$385.59
-
$385.59
Current price
$385.59
Thermistor Thermometer, Thermistor, Number of Channels 3, Includes NIST-Traceable Certificate Yes, Accuracy +/-0.3 Degrees F or +/-0.5 Percent of Reading Whichever is Greater, -40 Degrees to 300 Degrees F/-40 to 150 Degrees C, (1) 9V, 7/8 in H x 2 in W Display with 4-Digit Backlit LCD, Functions Degrees F/ Degrees C Switchable, Constant Scan Feature, Low Battery Indication, Min/Max Memory, Temperature Trend Indication, Resolution 0.1 Degrees
| Battery Type | (1) 9V |
| Includes | Model 1075 General Purpose Puncture Probe, Model 2010 Air Probe, Model 4011 Surface Probe |
| Temp. Accuracy | +/-0.3 Degrees F or +/-0.5% of Reading |
| Item | Thermistor Thermometer |
| Features | Measures Up to Three Temperatures Plus T1-T2-T3 Differential |
| Sensor Type | Thermistor |
| Temp. Range (C) | -40 Degrees to 150 Degrees |
| Resolution | 0.1 Degrees |
| Standards | ISO 17025 A2LA Accredited Calibration Laboratory |
| Temp. Range (F) | -40 Degrees to 300 Degrees |
| Display | LCD |
| Probe Connector | 1/8 in Phono Plug |
| Auto Power Off | Yes |
| Calibration Certificate | FDA |
| Display Type | LCD |
| Response Time | 0.5 sec |
| Data Hold | Yes |
| Memory | Min/Max |
| Accuracy | +/-0.3 Degrees F or +/-0.5% of Reading Whichever is Greater |
| Number of Digits | 4 |
| Power Source Details | (1) 9V Battery |
| Data Logging | No |
| Digital Display | 7/8 in H x 2 in W Display with 4-Digit Backlit LCD |
| Included Probes | Model 1075 General Purpose Puncture Probe, Model 2010 Air Probe, Model 4011 Surface Probe |
| Temperature Meter Type | Multichannel Thermistor Temperature Meter with Min/Max |
| For Thermistor Type | 10k Thermistor |
| Backlit | Yes |
| Includes NIST-Traceable Certificate | Yes |
| Includes Wireless Transmission | No |
| Includes Batteries | Yes |
| Functions | Degrees F/ Degrees C Switchable, Constant Scan Feature, Low Battery Indication, Min/Max Memory, Temperature Trend Indication |
| Number of Channels | 3 |
| Thermocouple Temperature Range F | -40 Degrees to 300 Degrees F |
| Thermocouple Temperature Range C | -40 Degrees to 150 Degrees C |
| Data Output Type | None |
| Temperature Range | -40 Degrees to 300 Degrees F/-40 to 150 Degrees C |
| RTD Temperature Range F | -40 Degrees to 300 Degrees F |
| RTD Temperature Range C | -40 Degrees to 150 Degrees C |
| Package Quantity | 1 |