Documenting process calibrators connect to a computer to transmit or export data for analysis, recordkeeping and storage, and allows calibration procedures to be programmed and automated. These calibrators monitor electrical quantities like voltage, current, and resistance, or check signals like pressure and temperature. They also act as a power source while measuring when a power supply is not present, has insufficient voltage to handle the loop test or needs to be switched off during testing.
| Includes | (2) AC280 Hook Clips, (3) Extended Tooth Alligator Clips, (3) TP220 Test Probes, 754HHC HART Communications Cable, Battery Charger, Carrying Case, USB Cable |
| Display | Graphical |
| Standards | ASNI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1-92, EN 610-1:1993, UL3111 |
| Interface | USB |
| Loop Supply Voltage | 26 V |
| RTD Type | Cu10 (427), Ni120 (672), Pt100 (385), Pt100 (3916), Pt100 (3926), Pt1000 (385), Pt200 (385), Pt500 (385) |
| Powered By | Rechargable Battery Pack |
| Current Measurement Range | 0 to 110mA DC |
| RTD Temperature Range | -200 Degrees to 800 Degrees C |
| Frequency Measurement Range | 0 to 50 kHz |
| Max. Loop Current | 24 mA |
| Thermocouple Temperature Range | -250 Degrees to 2500 Degrees C |
| Frequency Source Range | 0.01 to 50 kHz |
| Calibration Certificate | NIST |
| Source Current | 0 to 22mA DC |
| Intrinsically Safe | No |
| Insulation Category | Cat II 300V |
| Measurement Functions | Current, Frequency, Resistance, TC and RTD, Voltage (AC and DC) |
| External Pressure Range | Dependent On Pressure Module |
| Thermocouple Type | B, BP, C, E, J, K, L, N, R, S, T, U, XK |
| Resistance Source | 0 to 10 kilohm |
| Basic DC Accuracy | +/- 0.05% + 0.05V |
| Voltage Measurement Range | 0 to 300V AC/V DC |
| Resistance Measurements | 0 to 10 kilohm |
| Pressure Modules | 29 Ranges |
| Source Voltage | 0 to 15V DC |
| Shop By | Hot Buys |
| Loop Current - Maximum | 25 mA |
| Communication Protocol | HART |
| IP Rating | IP52 |
| Source Current - Maximum | 22 mA |
| Resistance Measurement - Minimum | 1 kiloohm |
| Thermocouple Temperature - Maximum | 1,472 Degrees F |
| Current Measurement - Maximum | 110 mA |
| Frequency Measurement - Minimum | 11.01 kHz |
| Source Voltage - Minimum | 1 V |
| Frequency Measurement - Maximum | 50 kHz |
| Resistance Measurement - Maximum | 10 kiloohm |
| Thermocouple Temperature - Minimum | 482 Degrees F |
| Source Resistance - Minimum | 1 kiloohm |
| Source Voltage - Maximum | 15 V |
| Current Measurement - Minimum | 30 mA |
| Battery Chemistry | Lithium Ion |
| Voltage Measurement - Minimum | 3 V AC/DC |
| RTD Temperature - Maximum | 1,472 Degrees F |
| Parameters Measured | AC Current, AC Voltage, DC Current, DC Voltage, Frequency, Resistance, RTD, TC |
| Includes Batteries | Batteries Included |
| Source Frequency - Maximum | 50 kHz |
| Source Resistance - Maximum | 10 kiloohm |
| Source Frequency - Minimum | 22 kHz |
| Digital Display Screen Type | LCD |
| Intrinsic Safety | Not Specified Intrinsically Safe |
| Voltage Measurement - Maximum | 300 V AC/DC |
| RTD Temperature - Minimum | -328 Degrees F |
| Source Current - Minimum | 0 mA |
| Calibration Certificate Type | NIST |