FLUKE-726/FPC Multifunction Calibrator Precision Multifunction, HART, 0.001 mA – 24 mA, NIST
Original price
$7,850.45
-
Original price
$7,850.45
Original price
$7,850.45
$7,850.45
-
$7,850.45
Current price
$7,850.45
Multifunction Calibrator, Voltage Measurement Range -10 to 75 mV, Loop Supply Voltage 24 V, Intrinsically Safe No, Pressure Modules 29, Measurement Functions Hertz, mV, Ohms, V, Source Current 24 mA DC, Current Measurement Range 0 to 24 mA DC, Basic DC Accuracy +/- 0.01 Percent + 2mV, Thermocouple Temperature Range -250 Degrees to 2500 Degrees C, Powered By (4) AA Batteries, Includes Alligator Clips, Stackable Test Leads, Test Leads, Frequency Source Range 10.0 to 15.0 kHz
| Includes | Alligator Clips, Stackable Test Leads, Test Leads |
| Standards | ASNI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992, EN 61010-1:1993 |
| Calibration Certificate | NIST |
| Thermocouple Type | B, BP, E, J, K, L, N, R, S, T, U, XK |
| RTD Type | Cu10, Ni120, Pt100 (385), Pt100 (391-JIS), Pt100 (392), Pt1000 (385), Pt200 (385), Pt500 (385) |
| Safety Rating | ANSI/ISA S82.01-1994, CAN/CSA C22.2 No 1010.1:1992, EN61010-1:1993 |
| Current Measurement Range | 0 to 24 mA DC |
| Source Voltage | -10 to 75 mV |
| Powered By | (4) AA Batteries |
| Pressure Modules | 29 |
| Measurement Functions | Hertz, mV, Ohms, V |
| Frequency Source Range | 10.0 to 15.0 kHz |
| Intrinsically Safe | No |
| Source Current | 24 mA DC |
| Voltage Measurement Range | -10 to 75 mV |
| Loop Supply Voltage | 24 V |
| Basic DC Accuracy | +/- 0.01% + 2mV |
| Max. Loop Current | 22 mA |
| Resistance Measurements | 0 to 4,000 ohm |
| Resistance Source | 1,500 to 4,000 ohm |
| Thermocouple Temperature Range | -250 Degrees to 2500 Degrees C |
| Source/Simulate | Hertz, mA, mV, Ohms, V |
| Frequency Measurement Range | 10.0 to 15.0 kHz |
| Number of Batteries Required | 4 |
| Resistance Measurement - Minimum | 0 ohm |
| Parameters Measured | DC Current, DC Voltage, Frequency, Pressure, Resistance, RTD, TC |
| Resistance Measurement - Maximum | 4,000 ohm |
| Source Current - Maximum | 24 mA |
| Frequency Measurement - Minimum | 1 kHz |
| Source Frequency - Minimum | 10 kHz |
| Source Voltage - Maximum | 75 mV |
| Current Measurement - Maximum | 24 mA |
| Frequency Measurement - Maximum | 15 kHz |
| Battery Chemistry | Alkaline |
| Voltage Measurement - Maximum | 75 mV |
| Loop Current - Maximum | 22 mA |
| Current Measurement - Minimum | 0 mA |
| Thermocouple Temperature - Minimum | 482 Degrees F |
| Source Resistance - Minimum | 1,500 ohm |
| Parameters Sourced | AC Voltage, DC Voltage, Frequency, Resistance |
| Source Resistance - Maximum | 4,000 ohm |
| Intrinsic Safety | Not Specified Intrinsically Safe |
| Thermocouple Temperature - Maximum | 4,532 Degrees F |
| Source Voltage - Minimum | -10 mV |
| Includes Batteries | Batteries Included |
| Calibration Certificate Type | NIST |
| Source Frequency - Maximum | 15 kHz |
| Digital Display Screen Type | LCD with Backlight |
| Source Current - Minimum | 0.001 mA |
| Voltage Measurement - Minimum | -10 mV |
| Communication Protocol | HART |