Tripp Lite ECO750UPSTAA UPS System, Standby, Desk Top/Tower, 750VA
Original price
$253.40
-
Original price
$253.40
Original price
$253.40
$253.40
-
$253.40
Current price
$253.40
UPS System, Standby, Power Rating 750 VA, Wattage 450 W, Input Voltage 120V AC, Output Voltage 115V AC, 120V AC, Backup Time (Half/Full Load) 11.5 min/2.5 min, Mounting Desktop/Tower, Outlet Type (6) Surge, (6) UPS/Surge, Number of Outlets 12, Medical Grade No, NEMA Receptacle Configuration 5-15R, NEMA Plug Configuration 5-15P, Automatic Volts Regulation No, Fax/Modem Line Protection Yes, Transfer Time 3 msec from Battery to AC, 6 msec from AC to Battery, Width 12 in, Depth 7 in, Height 3 in
| UPS Type | Standby |
| VA Rating - UPS Systems | 750.0 VA |
| Watts - UPS Systems | 450.0 W |
| Input Voltage - UPS Systems | 120V AC |
| Output Voltage - UPS Systems | 115V AC, 120V AC |
| Backup Time (Half/Full Load) | 11.5 min/2.5 min |
| Outlet Type - UPS Systems | (6) Surge, (6) UPS/Surge |
| Number of Outlets | 12 |
| Medical Grade | No |
| Footnotes | 4,6,9 |
| Includes | USB cable |
| NEMA Plug Configuration | 5-15p |
| Watts | 450W |
| Outlet Type | (6) Surge, (6) UPS/Surge |
| Mounting | Desktop/Tower |
| Ports | USB (HID enabled) |
| Item | UPS System |
| Input Current | 10 A |
| Mounting - UPS Systems | Desktop/Tower |
| Display Type | LED |
| Automatic Volts Regulation | No |
| Power Rating | 750VA |
| Green Environmental Attribute | Product Contributes To Reducing Energy Consumption |
| Transfer Time | 3 msec from Battery to AC, 6 msec from AC to Battery |
| NEMA Receptacle Configuration | 5-15R |
| Special Features | (4) Built-In ECO Outlets w/Auto Off, Poweralert Software |
| Input Voltage | 120VAC |
| Hz | 60 Hz |
| Phase | 1 |
| Output Voltage | 115V AC |
| Standards | CSA, FCC Part 15 Category B (EMI), NOM, TAA Compliant, UL 1778 |
| Fax/Modem Line Protection | Yes |
| Green Certification or Other Recognition | UL 1778CSAFCC Part 15 Category B (EMI)TAA, RoHS |
| Wattage | 450 W |
| Voltage | 120 |
| Backup/Run Time (Full Load) | 2.50 Minute/11.50 Minute |
| Capacity - Batteries | 750 VA/450 W |
| Input Connection | 6 ft Cord with NEMA 5-15P Plug |
| Battery Type | Valve Regulated Lead Acid (VRLA) |
| UPS Certifications | Tested to UL1778 (USA); Tested to CSA (Canada); Tested to NOM (Mexico); Meets FCC Part 15 Category B (EMI); TAA Compliant |
| DC System Voltage (VDC) | 12 |
| Output AC Waveform (Battery Mode) | PWM sine wave |
| Network UPS Tools Compatibility | NUT compatible. See the full list of Tripp Lite NUT compatible UPS systems at http://www.networkupstools.org/stable-hcl.html?manufacturer=Tripp Lite |
| Relative Humidity | 0 to 95%, non-condensing |
| Half Load Runtime (min.) | 9.4 min. (225w) |
| Input Phase | Single-Phase |
| Communications Cable | USB interface cable included |
| Frequency Compatibility | 60 Hz |
| UPS AC Suppression Response Time | Instantaneous |
| Expandable Runtime | No |
| Nominal Voltage Details | 115v nominal output in battery mode |
| Installation Form Factors Supported with Included Accessories | Tower; Ultra-compact desktop; Wallmount |
| Low Voltage Transfer to Battery Power (Setpoint) | 99 |
| Nominal Input Voltage(s) Supported | 120V AC |
| WatchDog Compatibility | Supports Watchdog application, OS and hard-reboot restart options for remote applications |
| UPS Input Connection Type | 5-15P; Right-Angled |
| Switches | Combination switch controls on/off power status and self-test operation; second recessed push-button switch enables ECO outlet switching |
| AC Mode Efficiency Rating (100% Load) | 0.99 |
| Primary Form Factor | Desktop |
| UPS AC Suppression Joule Rating | 420 |
| LED Indicators | 3 LEDs indicate power status, overload/check battery and ECO-mode status |
| Rated input current (Maximum Load) | 10A |
| UPS Housing Material | Plastic |
| UPS Dataline Suppression | 1 line TEL/DSL (1 in / 1 out) |
| Output AC Waveform (AC Mode) | Sine wave |
| Communications Interface | USB (HID enabled) |
| Operating Temperature Range | +32 to +104 degrees Fahrenheit / 0 to +40 degrees Celsius |
| Audible Alarm | Audible alarm indicates power-failure and overload status |
| Output Volt Amp Capacity (VA) | 750 |
| Nominal Output Voltage(s) Supported | 110V; 115V; 120V |
| EMI / RFI AC Noise Suppression | Yes |
| Individually Controllable Load Banks | No |
| Output Watt Capacity (Watts) | 450 |
| Output Voltage Regulation (Battery Mode) | +/- 5% |
| AC Mode BTU / Hr. (Full Load) | 3 |
| Output Receptacles | (12) 5-15R |
| Storage Temperature Range | +5 to +122 degrees Fahrenheit / -15 to +50 degrees Celsius |
| Battery Recharge Rate (Included Batteries) | Less than 16 hours from 10% to 90% |
| Cold Start (Startup in Battery Mode During a Power Failure) | Cold-start operation supported |
| High Voltage Transfer to Battery Power (Setpoint) | 139 |
| PowerAlert Software | For local monitoring via the UPSβ’s built-in USB port, download PowerAlert Local software at http://www.tripplite.com/poweralert |
| Recommended Electrical Service | 15A 120V |
| UPS Output Receptacles (Surge Suppression Only) | 6 UPS outlets, 6 surge-only outlets |
| USB | Yes |
| Plug/Connector Type | NEMA 5-15P |
| Typical Battery Recharge Time | 20 Hour |
| Dataline Protection | RJ-11 |
| Receptacle Detail | 6 x NEMA 5-15R |
| Product Series | ECO |
| Load Capacity | 750 VA/450 W |
| Certifications & Standards | UL 1778, CSA, FCC Part 15 Category B (EMI), TAA |
| Product Type | Standby UPS |
| TAA Compliant | Yes |
| Product Name | ECO750UPSTAA 750 VA Desktop ECO UPS TAA Compliant |
| Package Contents | ECO750UPSTAA 750 VA Desktop UPS, USB Cable, Instructional Manual with Warranty Information |
| Backup/Run Time (Half Load) | 11.50 Minute |
| Form Factor | Desktop |
| Runtime Half Load (min.) | 9.4 min. (225W) |
| High Availability UPS Features | Surge/noise protection |
| Output Capacity (Watts) | 450 |
| Output Capacity (VA) | 750 |
| Product Certifications | CSA (Canada); NOM (Mexico); UL 1778 |
| Product Compliance | FCC Part 15 Class B (USA); Trade Agreements Act (TAA) |
| UPS Applications | Computer/Peripherals |
| Package Includes | ECO750UPSTAA TAA Compliant UPS System;USB cable;Instruction manual |
| Runtime Full Load (min.) | 2.8 min. (450W) |